MIXPLANT - HTST Solutions

The most suitable solution for capacity starting from 1200 l/h.

Unlike the BATCH solution, the pasteurization temperature is reached in the plates and maintained for the necessary time in the coil.

The particular architecture of the heat flows allows to recover more than 40% of the energy needed to heat and cool the mixture.

HTST Technical Info

MIXPLANTHourly ProductionPreheating BoilerPasteurization BoilerTotal Installed PowerTower Water Consumption Compressed Air Consumption 6 bar Voltage Dimensions
l/hKcal/hKcal/hkWl/hNl/hV/Ph/Hzmm
600 HTST60060.00017.000142.500120400/3/506.000x2.300x2.120
1.200 HTST1.200100.00027.000223.600120400/3/507.800x2.300x2.120
2.000 HTST2.000141.00027.000376.000250400/3/508.250x2.400x2.950
2.400 HTST2.400160.00030.000427.000250400/3/508.250x2.400x2.950
3.000 HTST3.000210.00038.000509.000250400/3/5011.000x2.400x2.950
4.000 HTST4.000300.00050.0006412.000250400/3/5012.000x2.400x3.100
5.000 HTST5.000360.00060.0006815.000250400/3/5012.000x2.400x3.500

Homogeneizer Technical Info

OMOHourly CapacityMax PressurePistonsTotal PowerElectric VoltageLubrification Water ConsumptionCompressed Air Consumption 6 barDimensions
l/hbarnr.kWV/Ph/HzlNl/hmm
12012015021,2400/3/5012060400x525x750
20020018022,2400/3/5012060600x700x700
30030018022,2400/3/5012060600x700x700
60060018034400/3/5012060700x1.100x900
1.2001.20018037,5400/3/50120601.000x1.280x980
2.0002.000180311400/3/50250601.000x1.280x980